Aerospike Sink Connector
The Aerospike Sink connector is used to write messages to an Aerospike Cluster.
Sink Configuration Options
The following configuration options are specific to the Aerospike Connector:
| Name | Required | Default | Description | 
|---|---|---|---|
| seedHosts | true | null | Comma separated list of one or more Aerospike cluster hosts; each host can be specified as a valid IP address or hostname followed by an optional port number (default is 3000). | 
| keyspace | true | null | Aerospike namespace to use. | 
| keySet | false | null | Aerospike set name to use. | 
| columnName | true | null | Aerospike bin name to use. | 
| maxConcurrentRequests | false | 100 | Maximum number of concurrent Aerospike transactions that a Sink can open. | 
| timeoutMs | false | 100 | A single timeout value controls socketTimeoutandtotalTimeoutfor Aerospike transactions. | 
| retries | false | 1 | Maximum number of retries before aborting a write transaction to Aerospike. |